GN-787E quick-loading alcohol base material electric heating vaporization controller function description
The controller is a moisture-proof structure of the whole plastic shell, and has its own lead-out line, which is used for electric heating and alcohol-free gasification stove without fan, in addition to the functions of conventional heating, temperature measurement, temperature control, ignition output, electromagnetic pump gear output and the like. There is also a model with its own precision fire regulation to choose, which can realize the stepless precision adjustment and start and stop control of the oil pump flow. This function and the gear position adjustment realize the effect of no need to switch, fire with heart, and start and stop freely. At the same time, it can also extend the external word reset rocker switch or the third gear self-reset switch to achieve more convenient gear position control. There are also models with infrared anti-air burning to choose from, easy to achieve considerable energy savings.
The controller is quick and easy to install, stable, adaptable and user-friendly, and cost-effective enough to be a replacement for the alcohol-based fuel gasifier industry. Basic parameters 1, rated working voltage: AC220V 2, normal working voltage range: AC187-242V
3, the service life: the number of actions is not less than 100,000 times 4, heating output power: no more than 2000W
5, ignition output: AC220V, power is not more than 100W
6, electromagnetic pump output: AC220V, power is not more than 100W, full power range PWM voltage regulation 7, temperature probe: K-type thermocouple
8, personality function: external one-word rocker switch or three-speed self-reset switch need to buy, precision firepower adjustment function need to buy, infrared anti-air burning function need to buy Wiring instructions
1. Brown-blue black sheathed wire: Connected to 220V AC power supply, the leakage circuit breaker and a bipolar switch should be installed at the front end of the power supply to play the role of reliable control of the total power supply and safety protection.
2, brown-blue black sheathed wire with cold-pressed flat connector: plug-in burner aluminum ring heating wire, internal switching device adopts high-power relay, and adopts unique switch control technology, life is longer than conventional Greatly extended.
3. Brown-blue black sheathed wire with cold-pressed round connector: Plug-in electromagnetic pump, its output voltage is adjustable AC voltage, due to the unique micro-computer controlled high anti-interference non-contact PWM The power adjustment technology can obtain stable output even when the igniter is ignited, and there is no malfunction. Matching with commonly used imported electromagnetic pumps allows the electromagnetic pump to perform optimally.
4. Black sheathed cable with black combination connector: plug the 220V igniter.
5. Black sheathed wire with ring lug and blue soft sheath: Use the small screw to connect the split lug of the K-type thermocouple, pay attention to ensure the correct polarity.
6. Three-core black sheathed wire with split lug: Connect one-way two-way rocker switch or three-speed self-reset switch. The switch with the branch line is on the same side, and the other line with no branch is connected to the other side of the switch.
7. There are two black sheathed wires with waterproof joints, which are connected to the infrared emitting head and the receiving head with glass window. The receiving head is a four-core cable, which is connected by the attached special extension cable. The receiving head on the back panel. Setting instructions
The following instructions are all performed when the controller's settings are in the factory state, the controller is connected to the thermocouple, and the power is turned on. Whether other interfaces are connected or not connected does not affect the setting operation.
After the controller is powered on, all the digital tubes and LED indicators will be lighted up. You can use this opportunity to check whether there are any missing or missing lights. Finally, the digital tube displays OFF, which is the shutdown state. In this state, the setting operation cannot be performed.
Press the start/stop button in the off state, the system enters the heating or standby state, and the digital tube displays the current temperature value and the gear position value respectively. The current temperature value is the temperature measured by the current thermocouple. When the gear position value is not activated, the display is 0. . In this state, you can perform the setting operation:
1. Modify the output power parameter of the electromagnetic pump: press and hold the setting button for about 5 seconds, the red digital tube displays d-1, indicating that the first power output parameter setting menu is entered, and then press the setting button, the green digital tube displays the current output of the gear. The percentage of power, at this time press the increase and decrease buttons, the power output parameters can be adjusted between 0-100.
★ Parameter confirmation save: adjust the parameters, press and hold the setting button, the number starts to flash until the red display SAU, indicating that the parameter is saved successfully, and the system exits the setting state.
★ After adjusting the first gear parameters, if you need to adjust other gear parameters, you can press the setup button again to return to display d-1, and the data is temporarily stored. Press the increase/decrease button to enter d-2, d-3 and other gears in turn, and set the parameters according to the above method. Finally, press and hold the setting button until SAU is displayed, and all parameters are saved before one time.
★If the above operation does not long press the setting button and display SAU, the new parameters will not be officially saved. If there is no operation for a few seconds or the system is started by pressing the start/stop button, the system will still run according to the original parameters.
★ d-1 first file default value 28.5; d-2 second file default value 32.5; d-3 third file default value 36; d-4 fourth file default value 42; d-5 five file default value 44.
2, modify the underlying parameters: display d-5 and then press the minus button, the digital tube shows the SP begins to enter the underlying parameter settings menu, and then press the minus button to display Ao1, SC, HHH, ddH, odH, oPP, SPP, SoP, FHS , SEP and other menus.
1 SP menu is the target temperature value option; default value: 190 ° C; setting range: 130-300 ° C.
★Parameter meaning: heating to this temperature stops preheating.
★ At this time, press the setting button, the digital tube will display the target temperature value, press the increase or decrease button to change the parameter, and the parameter confirmation save method is the same as before. The same applies hereinafter and will be omitted.
★ If you do not press any button for 5 seconds, the setting state will be automatically exited, and the parameter will not be memorized.
2 Ao1 menu is the ignition start temperature value option; default value: 130; setting range: 100-190 °C.
★ Parameter meaning: After reaching this temperature value, it is allowed to start work.
3 SC menu is the error correction value option; default value: 0; setting range: ±20 °C.
★ The meaning of the parameter is: When the current temperature is found to be different from the value measured by the standard thermometer, this value can be set according to the error value to correct the current temperature value to reduce the error.
4 HHH menu is the high temperature protection value option; default value: 450; setting range: 300-500 °C.
★ The meaning of the parameter is: After the temperature is reached, the system automatically protects, and the system forcibly stops the electromagnetic pump output.
5 ddH menu is the delay ignition time option; default value: 0; setting range: 0-20 seconds.
The meaning of the parameter is: After the electromagnetic pump is working, the ignition output will be started after the corresponding time delay.
6 odH menu is the continuous ignition time option; default value: 6; setting range: 1-20 seconds.
The meaning of the parameter is: After the electromagnetic pump is working, the ignition output will stop after the corresponding time.
7 The oPP menu is the boot gear option; the default value is 2; the setting range is 0-5.
The meaning of the parameter is: the output power gear value of the electromagnetic pump at the time of starting.
8 SPP menu is the shutdown gear option; default value: 1; setting range: 0-1.
The meaning of the parameter is: 1 is automatically returned to the second gear after shutdown, and then the second gear is started. 0 is to keep the original gear after the shutdown, and then the original gear is activated.
9 SoP menu is the startup mode option; default value: 1; setting range: 0-1.
The meaning of the parameter is: when the parameter is 0, the system can only be started by pressing the start/stop button or by the precision adjuster; when the parameter is 1, the system adds the function that can be started by pressing the add button, the rocker switch or the right-hand precision adjuster. .
10 FHS menu is soft and hard start option; default value: 1; setting range: 0-1.
The meaning of the parameter is: 0 is a hard start, that is, booting directly from the start gear. 1 is a slow start, that is, it automatically rises from the 2nd gear slowly when it is turned on, until it increases to the gear position before the shutdown. Slow start is only valid when the SPP parameter option is 1.
11 SEP menu is a precision adjusted speed option; default value: 3; setting range: 1-30.
The meaning of the parameter is: the adjustment amount corresponding to the minimum angle of rotation of the external precision regulator can also be understood as the speed adjusted during rotation. The smaller the value, the finer the adjustment and the slower, and vice versa.
3, restore the factory settings: the controller is powered off, press and hold the minus button at the same time to turn on the power, display the rEc release button, long press the set button until the display SAU means that the factory settings are successful, all the parameters can be set at this time Both returned to the factory state.
Working process: Description under factory settings
Power on to the OFF state, press the Start / Stop button to enter the preheating state, the heating lamp lights up, the digital tube displays the current temperature and gear position, the output of the heating tube has an output of 220V to start heating, when the temperature reaches 130 °C, the status light Start flashing, the prompt can start the work manually, press the “Start/Stop” button or the key or fine adjustment knob to start, the status light turns to steady after the start, the ignition and the electromagnetic pump vaporization start to have the output and the corresponding indicator. Lights up, after 6 seconds, the ignition output stops, the indicator light goes out, and it enters the combustion state. At this time, the output of the heating tube still has an output, and the heating lamp is still lit until the current temperature reaches the desired target temperature to stop the heating output and extinguish the heating lamp.
After the current temperature reaches the target temperature, if the operation is not started by pressing the “Start/Stop” button, the system enters the thermal insulation working state, and the heating and heating is automatically performed. The temperature of the burner is always maintained near the target temperature, ready to start working.
Firepower adjustment method: 1 Press the “increase or decrease” button during the combustion process, and the firepower will gradually increase and decrease the gear position according to the set value of the gear position. 2 Rotate the fine adjustment knob during the combustion process, the firepower can be continuously and smoothly adjusted.
Stop method: 1 Press the “Start/Stop” button during combustion. 2 Press “fine adjustment knob” during combustion. 3 In the combustion, turn the “fine adjustment knob” counterclockwise to the minimum firepower, and then rotate. 4 In the first state of combustion, press the “minus” button. 5 In the first stage of combustion, operate the rocker switch to downshift.
Power-on method: Press the “Start/Stop” button when the 1 status light is flashing. 2 Press the “fine adjustment knob” when the status light is flashing. 3 Turn the “fine adjustment knob” clockwise when the status light is flashing. 4 Press the Add button while the status light is flashing. 5 When the status light is flashing, operate the rocker switch to increase the gear.
After using the above 12 shutdown and then booting, it is started from the system default gear.
After using the above 345 to shut down and then boot, it is started from the first gear.
Shutdown method: Press and hold the “Start/Stop” button or “fine adjustment knob” for about 3 seconds during the stop or combustion work, and the system will enter the OFF state. Precautions:
★The temperature value does not rise and fall during the heating process, indicating that the polarity of the thermocouple is reversed, and the “LLL” will be displayed later.
★ The thermocouple open circuit will display HHH and the system protection will stop. It needs to be restarted after the fault is removed.
★When the highest-grade setting value is too large, the pump oil will exceed the head's vaporization capacity, and the flame yellowing instability will occur.
★When the starting temperature setting value is too low, the flame will be unstable due to insufficient vaporization.
★ If you find that the flame is unstable when you just click it, you can set the ignition to delay 1-2 seconds to start the ignition, so you can avoid the knocking phenomenon at the moment of starting. Especially for models with air defense, it is necessary to set up this frequently because of the frequent start-up. Practice shows that this works well.
More than 95 of the ovens are suitable for this igniter. Check the parameter fan voltage 220V, solenoid valve voltage 24V, solenoid valve is 12V can also be used You can use this igniter! Features: used in gas water heaters, gas ovens applicable to New South, Dewey, Hongling, Honglian, Henglian, Mingtai, Bao, Xiangxing, Debao, Baozhu, Kitchen Po, Lijia, Nanguo Baoli Gas ovens, etc., with automatic ignition and fault alarm function, adopt American PIC chip, have stable performance, strong anti-interference ability, high reliability, safety and stability, and convenient system design. The pulse igniter is a gas oven control system, which [...]
68.13 $ Add to cartDQ8 basic parameters The DQ8 high-energy igniter developed by the company is AC220V igniter, with strong ignition capability, stable and reliable performance and high ignition efficiency. It is widely used in commercial energy-saving stoves, boilers, burners, steamers, ovens and other commercial equipments that use gas and methanol as fuel. 1, product model: DQ8. 2, the main function: delay super ignition, low-voltage switch start. 3, working voltage range: AC175V-245. 4, the service life: ≥ 100,000 times. 5, ignition intensity: super ignition, can ignite flammable gas and various alcohol-based biofuels. 6, ignition high pressure: ≥ 15Kv. 7, delay to stop the ignition [...]
78.75 $ Add to cartFunctional Overview BF-15B + microcomputer temperature difference controller, directly set the temperature difference upper limit to achieve the effect of temperature control of the water cycle, the panel is simple and convenient to operate. To make hot and cold water cycle, mainly by improving the thermal efficiency high and low temperature difference between the value measured by the sensor and the upper and lower limit set temperature difference. Mainly used in hot water circulation system backwater control. The main function Function Name Function Description Temperature control when the temperature difference T ≤T limit, normally open relay disconnected, normally closed pull; [...]
82.00 $ Add to cartZQ1 alcohol based fuel steam controller system description First, the configuration: 220V electromagnetic pump; 220V fan; super ignition; start button compatible switch; wind pressure switch; lower water level probe; ignition needle; fire needle; status indicator. Second, the applicable products: Alcohol based fuel steam generator Third, the work process: When the start button is turned on, the fan runs immediately. When the wind pressure switch is turned on, the ignition starts and the 220V electromagnetic pump is started, and the alcohol-based fuel is sprayed. When the fire detector detects the flame controller, the ignition is stopped, and the system enters the [...]
96.25 $ Add to cartBasic parameters 1, rated working voltage: AC220V 2, normal working voltage range: AC187-242V 3, the service life: the number of actions is not less than 100,000 times 4, fan power: no more than 600W 5, ignition output: AC220V, power is not more than 100W 6, electromagnetic pump / valve output: AC220V, power is not more than 100W 7, circulating water pump output: AC220V, power is not more than 1000W Wiring instructions 1. Brown-blue black sheathed wire: Connected to 220V AC power supply, the leakage circuit breaker and a bipolar switch should be installed at the front end of the power [...]
140.00 $ Add to cartAlcohol base material without fan electrification controller function description The controller is a moisture-proof structure of the whole plastic shell, and has its own lead-out line, which is used for electric heating and alcohol-free gasification stove without fan, in addition to conventional heating, temperature measurement, temperature control, inside igniter ignition high-voltage output, electromagnetic pump In addition to the functions such as built-in, there is also a model with its own precision fire regulation, which can realize stepless precision adjustment and start/stop control of the oil pump flow. This function and gear position adjustment realizes no need to switch, fire with [...]
415.00 $ Add to cartDescription: Features: 1 out 1 and 1 out 2 can be freely used, can be used. This product is a piezoelectric igniter, the external material is PP plastic, mainly used in gas stoves / ovens, with an ignition needle to play an ignition role. Specifications: Item Type: Piezo Spark Ignition Set Material:Plastic Cable Length: 1 m/3.3feet Output Terminals: 2.3 mm/0.09inch Installation Hole: 18 mm/0.71inch Output Voltage: ≥18KV3PF Type: 1 Out [...]
360 Rotation BBQ Lighter USB Windproof Flameless Kitchen Plasma Ignition for Gas Stove Candle size: Length 260mmProduct material: aluminum + zinc alloyProduct packaging: Blister packagingCharging port: type-CNote:Due to the different monitor and light effect, the actual color of the item might be slightly different from the color showed on the pictures. Thank you!Please allow 1-2cm measuring deviation due to manual measurement. 1 X BBQ Lighter 1 X [...]
N series atomization controller description This series of controllers is used in conjunction with a methanol spray burner for ignition and fire regulation. With the extinguishing function, it can be used in places such as steaming furnaces. System parameter setting method: Press and hold the setting button to enter the system parameter setting, turn the knob to select the desired menu, press the setting button to display the value, turn the knob to adjust the value, and then press and hold the setting button until the SAU is displayed, indicating that the saving is successful. Note: If you do not [...]
177.50 $ Add to cartFunction description of alcohol-based fuel vaporization controller for precise regulation of firepower The controller is used for electric heating and alcohol-free gasification stove without fan, in addition to the functions of conventional heating, temperature measurement, temperature control, ignition, electromagnetic pump speed regulation, etc., it can also expand external precision regulator to achieve precise adjustment of oil pump flow and Start-stop control, this function and gear position adjustment achieve the effect of no need to switch, fire with heart, start and stop freely. At the same time, it can also extend the external word reset rocker switch or the third gear [...]
477.50 $ Add to cartChcę coś kupić ale szukam informacji jak zamówić... |
Kupiłem coś ale chcę poznać status zamówienia... |
Odebrałem paczkę ale mam pytanie lub problem... |
Chcę dokonać zwrotu i potrzebuję informacji... |
Droptech Sp. z o.o. droptech.polska@gmail.com |
ul. Łódzka 118, Piotrków Tryb. Sprzedajemy tylko przez internet |
NIP: 7712911090 REGON 386758083 |
Wysyłka bezpośrednio od producenta lub dostawcy |
DARMOWA WYSYŁKA + ubezpiecznie dostawy + śledzenie przesyłki |
CAŁKOWITY ZWROT podczas reklamacji |
Reviews
There are no reviews yet.